Swedish First Hill Campus Power Monitoring System Replacement Project
Replacement of existing legacy campus power monitoring system with a new, state of the art system integrated with the campus emergency power system to initiate required monthly ATS testing and generate NFPA compliant monthly reports meeting CMS/DNV documentation requirements. A new Schneider Power Monitoring Expert (PME) system was selected through a competitive RFP bidding process. Scope of work included a new system head end providing real time visibility of the campus normal and emergency power…
Read MoreCreative Energy–Swedish First Hill Campus Carbon Neutral Energy District Project
EBD Services is providing Project Management and Electrical Design Engineering Services supporting the development of a carbon neutral energy district serving the First Hill neighborhood and the migration of the Swedish First Hill Campus toward carbon neutrality. Key elements of the project include a replacement of legacy mechanical plant systems to maximize the use of waste heat and high efficiency heat pumps including ambient loop. Major improvements to normal and emergency power system are coordinated…
Read MoreSwedish First Hill Southwest Tower Facility Condition Assessment
A facility condition assessment for MEP Systems and spaces serving the existing 250,000 square foot Southwest Tower located on the Swedish First Hill Campus was completed utilizing EBD Services customized FCA assessment program. Phase 1 effort includes record document review, CMMS asset data collection, physical site investigation to verify asset condition, asset and systems analysis, and scoring of MEP system assets. Phase 2 effort includes developed of a strategic multi-year capital replacement program focused on…
Read MoreSwedish First Hill Campus Building Analytics Program
EBD Services provided electrical systems engineering expertise to understand existing campus electrical power demand and assist in identifying opportunities for mechanical and lighting systems to reduce total electrical energy consumption and peak demand use in support of this initiative led by MacDonald Miller Facility Solutions. Project scope included the enrollment of the First Hill Campus into the Seattle City Light Pay For Performance program. This program included the award of significant rebates which were used…
Read MoreSwedish First Hill Campus MEP Systems Masterplan
Our Mechanical and & Electrical team completed an 11-month evaluation of existing campus MEP systems including campus normal service and emergency generator plant and distribution, supply air, chilled water, heating water, domestic water, medical gas, and BAS control systems. The project established campus strategic objectives for replacement/refurbishment of existing systems to improve campus system resiliency, energy efficiency, and coordination with future planned renovation and major expansion projects on the First Hill campus.
Read MoreProvidence Puget Sound Region Facility Condition Assessment
Campus Facility Condition Assessment for over 2.5 million square feet across multiple Providence Hospital Campuses including Providence Everett Colby Campus, Providence Everett Pacific Campus, Providence St. Pete’s (Olympia, WA), and Providence Centralia. Scope of work includes review of campus acute care buildings fixed MEP Assets and Spaces utilizing EBD Services customized FCA asset program, and development of a prioritized replacement strategy for legacy campus MEP Systems to inform strategic multi-year capital budget planning. Phase 1…
Read More